- Home
- Products
- Diagnostic
- Viral Pathogens
- RoboGene HCV RNA Quantification Kit 3.0
RoboGene HCV RNA Quantification Kit 3.0
- RoboGene HCV RNA Quantification Kit 3.0
- CE Certiication
- Declaration of Conformity
- Contact form
RoboGene HCV RNA Quantification Kit 3.0
Product description
RoboGene HCV RNA Quantification Kit 3.0 The RoboGene HCV RNA Quantification Kit 3.0 is intended for real-time PCR quantification of Hepatitis C Virus (HCV) RNA in human EDTA- or citrate plasma and serum samples. For specimen purification the manual method (INSTANT Virus RNA/DNA Kit) as well as the automated method (INSTANT Virus RNA/DNA Kit – FX) is validated. For amplification and detection the RoboGene HCV RNA Quantification Kit 3.0 is validated on the following real-time PCR devices: qTOWER 2 & 3; CFX96; LightCycler® 480; 7500 Fast, Rotor-Gene® 3000/6000/Q; RealLine Cycler 48-4/48-5/96-4/96-5 and QuantStudio 5.
The assay is purposed for the clinical management of patients with chronic HCV in conjunction with clinical presentation and other laboratory markers for HCV infection.
This test is intended to assess viral response to antiviral treatment as measured by changes in plasma and serum HCV RNA levels. Furthermore, in a course of antiviral therapy the probability of a sustained viral response can be judged.
The RoboGene HCV RNA Quantification Kit 3.0 is not intended for use as a screening test for the detection of HCV RNA in blood or blood products or as a diagnostic test to confirm the presence of HCV infection.
Status
CE-IVD
Validated extraction kits
| Automization | manual | automized | ||
| Extraction kit name | INSTANT Virus RNA/DNA Kit | INSTANT Virus RNA/DNA Kit -FX | ||
| Sample volume | 400 µl | 800 µl | ||
| Sample specimen | Plasma (EDTA, Citrate) and Serum | Plasma (EDTA, Citrate) and Serum |
Specifications
- LoD with manual purification: 13.6 IU/ml
- LoD with automated purification: 11.7 IU/ml
- Linear range: 50 to 4×1010 IU/ml
- Genotypes: 1-8
Piattaforme qPCR validate
- qTOWER³ (Analytik Jena)
- CFX 96 touch (Biorad)
- LightCycler® 480 (Roche)
- 7500 Fast (Applied Biosystems)
- Rotor-Gene® 3000/6000/Q (Corbett Research/Qiagen)
- RealLine Cycler 48-4/48-5/96-4/96-5
- QuantStudio 5
Order Info
| Code | Description | Format |
| 847-0207610032 | RoboGene® HCV RNA Quantification Kit 3.0 | 32 rxns |
| 847-0207610096 | RoboGene® HCV RNA Quantification Kit 3.0 | 96 rxns |
| 847-0207610192 | RoboGene® HCV RNA Quantification Kit 3.0 | 192 rxns |
Related Products
Ask to us for more information
Cerca nel sito
CATEGORIE PRODOTTI
- Life Science
- Epigenetics Antibodies
- Diagnostic